In previous versions of the IECC code and ASHRAE 90.1 Standard, it was easier to obtain lower
![ashrae 90.1 u values ashrae 90.1 u values](https://d3i71xaburhd42.cloudfront.net/976c1aa95fe9e5d217ac93b4bc6004b24344e8e2/110-TableA.2-1.png)
There are some major changes to envelope performance in the latest code cycle. In a long tab banded system the purlins are left exposed (Figure 2). Banding on the bottom of the purlins provides support. Multiple layers of unfaced and/or faced (air barrier) metal building insulation is installed on top of the supporting fabric and banding filling the cavity. The purlins are covered by the fabric vapor retarder in a banded liner system (Figure 1).Ī long tab banded system is a single or multi-layer filled cavity system where the first layer is laminated metal building insulation installed parallel and between the purlin space. The long tab vapor retarder is joined or seamed on top of the purlins. A second layer of unfaced insulation may be placed on top of the first layer and perpendicular to the purlins. In a banded liner system, large panels of fabric or other vapor retarder material is supported by banding, and installed underneath the purlins. Both options fulfill the metal building insulation U-value code requirements, so the system selected boils down to budget and preference. Most long tab banded systems typically do not offer fall protection. One key difference is that certain banded liner systems also qualify as OSHA-compliant fall protection systems. Liner Systems and Long Tab Banded Systems: What’s the Difference?įirst, liner systems are typically proprietary and must meet ASHRAE’s requirements in order to be defined as a liner system. Long tab banded systems are usually non-proprietary and meet the specifications of a filled cavity system.īoth systems provide High-R insulation to help meet stringent energy codes.
![ashrae 90.1 u values ashrae 90.1 u values](https://d3i71xaburhd42.cloudfront.net/13a893a40631e9f8f02e450c25e351ee41039b76/18-Table4.1-1.png)
Once that decision is made, the entire building, including the envelope and mechanical systems and lighting, must follow the same path. The building designer will have to make the decision to pursue either IECC 2015 or ASHRAE 90.1-2013. The choices are the same for the rest of the envelope. If you haven’t used filled cavity systems such as liner systems or long tab banded systems in the past, you will be required to start using them. This is a large jump, and many metal building contractors will feel the pressure. Several states currently at the IECC 2009 code are bypassing IECC 2012 altogether and adopting IECC 2015. If your state’s current code is based on the older IECC 2009 and ASHRAE 90.1-2007 Standard, you will see more significant envelope changes. An Overview: IECC 2015 and ASHRAE 90.1-2013įirst, it’s important to know that I base the most recent code cycle changes on comparisons of the IECC 2012 code and the ASHRAE 90.1-2010 Standard. The new code cycle will be effective in Georgia on January 1, 2018. Vermont (state-specific code modeled after IECC 2015).The following states have adopted the newer energy codes:
![ashrae 90.1 u values ashrae 90.1 u values](https://designbuilder.co.uk/helpv4.6/Content/Resources/Images/A901Constructions.png)
This article focuses on changes to roof and wall assembly code requirements, but remember that there are updates to other elements of the building envelope that you should also be aware of. Additionally, there are many elements within the building envelope subject to energy code regulations: There are 3 major components of an energy code: lighting, HVAC, and building envelope. This means that IECC is ultimately a more stringent code than the ASHRAE Standard.
#ASHRAE 90.1 U VALUES PLUS#
![ashrae 90.1 u values ashrae 90.1 u values](https://www.mdpi.com/sustainability/sustainability-13-10050/article_deploy/html/images/sustainability-13-10050-g012.png)
The IECC is a model energy code that references the ASHRAE 90.1 Standard. Check the status of your state energy code at .īefore we cover which states have adopted the latest code cycle, let’s briefly review some energy code basics.įirst, ASHRAE 90.1 is a minimum standard of energy efficiency, not a code. Theoretically, your state could switch in the next few months or in a few years. Remember that each state is in a code cycle, which lasts 2 to 3 years or more. For some states, the new code has already gone into effect as of January 1, 2017, but the exact timing of implementation depends on each state. The next commercial energy code cycle for most states is the International Energy Conservation Code (IECC) 2015 code and ASHRAE 90.1-2013 alternative path.